NG-5/10/30/50CCD FA – Macro Vickers Hardness Tester – Fully Automatic

$39,062.00

Select an option for member price

Available in 5/10/30/50 kgf configurations, the NG-5/10/30/50CCD FA is a Fully Automatic Macro Vickers hardness testing system that combines a CCD camera with optical analysis software and automated Z-axis focus control for true hands-off testing. Measurements can be completed through the analysis software from the live indentation image (with optional eyepiece viewing), helping reduce operator influence and improve repeatability. Built on the NG-5000 platform with an automatic motorized turret and built-in printer, the FA model is engineered for high-throughput quality control laboratories that require maximum automation, consistent results, and streamlined documentation.

Apply for Discount
SKU: N/A Category:

Description

NG-5/10/30/50CCD FA

Overview

The NG-5/10/30/50CCD FA series is the fully automatic configuration of our NG-5000 Macro Vickers platform. It builds on the capabilities of the CCD SEMI system and adds automated Z-axis focus control for a more hands-off, repeatable workflow. This lineup is designed for laboratories that want maximum throughput and consistency for Macro Vickers hardness testing, while maintaining high measurement confidence through CCD imaging and analytical software.

Standards

ASTM E384, ASTM E92, ISO 6507

What Makes the FA Model Different

The FA configuration delivers all of the benefits of the NG-5/10/30/50CCD SEMI and adds automated Z-axis control
to manage focus automatically. That means less operator intervention, improved repeatability across shifts and operators, and a smoother
path to consistent results during multi-point testing, pattern routines, and structured test plans.

How It Works

  • Position & secure the specimen: Set up your sample on the stage for testing.
  • Automated focusing (Z-axis): The system can automatically control focus to support a more hands-off workflow.
  • CCD + software measurement: Use the CCD camera and analysis software for clear indentation imaging and evaluation (eyepiece measurement is also available).
  • Motorized XY movement: Execute organized test layouts with repeatable movement between points for cleaner maps and faster routines.
  • Document results: Support reporting and documentation workflows for QA/QC and production environments.

Built for High-Throughput QC and Repeatability

The NG-5000 platform is engineered for accuracy and ease of use, with a workflow built for labs that run frequent hardness checks and need
consistent outputs. The FA lineup is a strong fit for production quality environments, process validation programs, and laboratories that
want maximum consistency without the variability of manual focus adjustment.

Data & Documentation

The NG-5000 Series is designed for practical documentation and data handling. Results can be printed for traceability, and the system can
be connected to a computer to support streamlined reporting workflows.

NG-5/10/30/50CCD FA

NG-5CCD FA

Overview

The NG-5CCD FA brings the fully automatic FA workflow to the 5 kgf-class Macro Vickers configuration. It combines CCD camera imaging + analytical software, a motorized XY stage, and automated Z-axis focus control to support structured routines with minimal operator intervention—ideal for QC labs that prioritize consistency and throughput.

Standards

ASTM E384, ASTM E92, ISO 6507

Best For

  • Routine QC checks with repeatable test maps
  • Structured multi-point programs where consistent focus is critical
  • Labs that want the benefits of CCD measurement without manual focusing variability

NG-10CCD FA

Overview

The NG-10CCD FA is the fully automatic Macro Vickers solution for the 10 kgf-class configuration. It uses the same FA workflow—CCD optical analysis, motorized XY positioning, and automated Z-axis focus—to support faster, more repeatable test routines with consistent results across operators and shifts.

Standards

ASTM E384, ASTM E92, ISO 6507

Best For

  • Production QA programs that need stable, repeatable operation
  • Higher-throughput test schedules with structured layouts
  • Labs that want automated focus for consistency and speed

NG-30CCD FA

Overview

The NG-30CCD FA extends the fully automatic workflow to the 30 kgf-class Macro Vickers configuration. It is designed for labs that need higher-load capability while maintaining the speed and repeatability benefits of CCD optical analysis, motorized XY movement, and automated Z-axis focus control.

Standards

ASTM E384, ASTM E92, ISO 6507

Best For

  • Higher-load Macro Vickers routines with structured multi-point programs
  • Labs that want less operator variability and faster repeatable test execution
  • Process validation environments that require consistent, documented workflows

NG-50CCD FA

Overview

The NG-50CCD FA is the highest-capability fully automatic model in the NG-5000 CCD FA lineup. It delivers the complete workflow—CCD camera measurement and analysis software, motorized XY stage, and automated Z-axis focusing—to support demanding production and laboratory environments that require repeatable results with minimal operator involvement.

Standards

ASTM E384, ASTM E92, ISO 6507

Best For

  • High-demand QC programs where throughput and repeatability are critical
  • Structured test plans that benefit from automated focusing and motorized positioning
  • Labs that want the most hands-off workflow available in the NG-5000 Macro Vickers platform
NG-5CCD FA NG-10CCD FA NG-30CCD FA NG-50CCD FA
Testing Forces 300g (1.96N), 500g (4.9N), 1kg (9.8N), 2kg (19.6N), 3kg (29.4N), 5kg (49N) 0.3kg (2.94N), 0.5kg (4.9N), 1kg (9.8N), 3kg (29.4N), 5kg (49N), 10kg (98N) 1kg (9.8N), 2kg (19.6N), 3kg (29.4N), 5kg (49N), 10kg (98N), 30kg (294N) 1kg (9.8N), 2kg (19.6N), 3kg (29.4N), 5kg (49N), 10kg (98N), 30kg (294N), 50kg (490N)
Vickers Scales HV0.3, HV1, HV2, HV3, HV5 HV0.3, HV0.5, HV1, HV3, HV5, HV10 HV1, HV2, HV3, HV5, HV10, HV20, HV30 HV1, HV2, HV5, HV10, HV20, HV30, HV50
Conversion Conversion of Vickers value to: HRA, HRC, HRD, HK, HBS, H15N, H30N, H45N, H15T, H30T, H45T
Minimum Measuring Unit 0.01μm
Vickers Value Range 1HV - 4000HV
Eyepiece 10x Magnification Eyepiece
Objectives 10x (Observation) and 40x (Measurement)
Vickers Value Displayed on the instruments display as well as the computer software (CCD)
Magnification 100X (Observation), 400X (Measurement), (Can be extended to 150X or 600X)
Loading Method Automatically - Load, dwell and unload the testing force
Duration 1-99 seconds
Turret Automatic Motorized Turret - Objective Lenses and Indenter
Maximum Height of Specimen 8.5cm
Maximum Depth of Specimen 12cm
Light Source LED Cold light source (no heat generated from light source - service life of light source can reach 100,000 hours)
Stage Dimensions of the X-Y Testing table are 10cmx10cm Maximum Travel Range 2.5cm x 2.5cm Moving Resolution Ratio 0.1mm
Warranty 12 Months
Power Source 110V/60Hz/1Ph
Overall Dimensions 19.3“ x 7.3“ x 20.3“ / 49 x 18.5 x 51.5 cm (LxWxH)
Weight 100lbs / 45kg
Optional Items 15x Eyepiece